ASTM D2420-23 - 1.3.2023
 
Significance and Use

5.1?Liquefied petroleum gases and their products of combustion must not be unduly corrosive to the materials with which they come in contact. The potential personnel exposure hazards of H2S also make the detection and measurement of hydrogen sulfide important, even in low concentrations. In addition, in some cases the odor of the gases shall not be objectionable. (See Specification D1835 and GPA 2140.)

 
1. Scope

1.1?This test method2 covers the detection of hydrogen sulfide in liquefied petroleum (LP) gases. The sensitivity of the test is about 4 mg/m3 (0.15 to 0.2 grain of hydrogen sulfide per 100 ft3) of gas.

1.2?The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.

1.3?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

D1193-06(2018)

Standard Specification for Reagent Water

GPA 2140

Liquefied Petroleum Gas Specifications and Test Methods

D1835-22

Standard Specification for Liquefied Petroleum (LP) Gases

D1265-23a

Standard Practice for Sampling Liquefied Petroleum (LP) Gases, Manual Method (Includes all amendments and changes 1/30/2024).