ASTM D4167-21 - 1.9.2021
 
1. Scope

1.1?This specification covers centrifugal and axial fans and blowers with airstream components fabricated of fiber-reinforced thermoset plastics (FRP) for corrosion resistance. It is acceptable for internal structures to include encapsulated metal fastening devices, hubs, and shafts.

1.2?Reinforcing materials other than fibrous glass are acceptable for use in the fabrication, provided the fans and blowers produced meet all the requirements of this specification.

1.3?The term fans as used in this specification includes fans and blowers, both centrifugal and axial.

1.4?The purpose of this specification is to provide purchasers, system designers, specifiers, and suppliers of FRP fans with minimum standards for fan construction and a common basis for determining safe operating speeds.

1.5?The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are provided for information only.

Note 1:?There is no known ISO equivalent to this standard.

Note 2:?Appendix X2 contains a list of documents potentially of interest to designers of fan systems.

1.6?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

D883-25b

Standard Terminology Relating to Plastics (Includes all amendments and changes 11/20/2025).

C582-23

Standard Specification for Contact-Molded Reinforced Thermosetting Plastic (RTP) Laminates for Corrosion-Resistant Equipment

NFPA91

Standard for Exhaust Systems for Air Conveying of Vapors, Gases, Mists, and Particulate Solids Available from National Fire Protection Association (NFPA), 1 Batterymarch Park, Quincy, MA 02269, http://www.nfpa.org.

ACGIH Industrial Ventilation:

A Manual of Recommended Practice Available from American Conference of Governmental Industrial Hygienists (ACGIH), 1330 Kemper Meadow Dr., Cincinnati, OH 45240, http://www.acgih.org.

Methods for Calculating Fan Sound Ratings from Laboratory Test Data

Reverberant Room Method for Sound Testing of Fans

AMCA Bulletin 210

Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Rating Available from Air Movement and Control Association International, 30 West University Dr., Arlington Heights, IL 60004, http://www.amca.org.

AMCA Fan and Air System Applications Handbook

(AMCA 200, 201, 202, 203)

D2563-08(2015):2015/ADJD2563

Adjunct to D2563 Practice for Classifying Visual Defects in Glass-Reinforced Plastic Laminate Parts

AMCA99

Standards Handbook