1. Scope

1.1 This test method covers the laboratory determination of the viscosity of engine oils at 150°C and 1 X 10 s -1 shear rate using a tapered bearing simulator-viscometer (TBS Viscometer) equipped with a refined thermoregulator system. Older TBS units not so equipped must use Test Method D4683-87.

1.2 The Newtonian calibration oils used to establish this test method cover the range from approximately 1.5 to 5.6 cP (mPa[dot]s) at 150°C.

1.3 The non-Newtonian reference oil used to establish this test method has a viscosity of approximately 3.5 cP (mPa[dot]s) at 150°C and a shear rate of 1 X 10 s -1 .

1.4 Applicability to petroleum products other than engine oils has not been determined in preparing this test method.

1.5 This test method uses the centipoise (cP) as the unit of viscosity. For information on the equivalent SI unit, the millipascal second (mPa[dot]s) is shown in parentheses.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

D4741-21

Standard Test Method for Measuring Viscosity at High Temperature and High Shear Rate by Tapered-Plug Viscometer

D6708-24

Standard Practice for Statistical Assessment and Improvement of Expected Agreement Between Two Test Methods that Purport to Measure the Same Property of a Material

D5481-21

Standard Test Method for Measuring Apparent Viscosity at High-Temperature and High-Shear Rate by Multicell Capillary Viscometer

D6300-26

Standard Practice for Determination of Precision and Bias Data for Use in Test Methods for Petroleum Products, Liquid Fuels, and Lubricants