ASTM D4798-01 - 10.11.2001
 
1. Scope

1.1 This test method covers test conditions and procedures for xenon-arc exposures according to Practice G151 and G155 for bituminous roofing and waterproofing materials having a minimum softening point of approximately 95°C (200°F) as determined by Test Method D36.(Also see Terminology G113.)

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

G113-24

Standard Terminology Relating to Natural and Artificial Weathering Tests of Nonmetallic Materials

G141-09(2021)

Standard Guide for Addressing Variability in Exposure Testing of Nonmetallic Materials

G147-24

Standard Practice for Conditioning and Handling of Materials for Natural and Artificial Weathering Tests

G151-26

Standard Practice for Exposing Materials in Accelerated Test Devices that Use Laboratory Light Sources

G155-25

Standard Practice for Operating Xenon Arc Lamp Apparatus for Exposure of Materials

D36-06

Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus)

D1669-07

Standard Practice for Preparation of Test Panels for Accelerated and Outdoor Weathering of Bituminous Coatings

D1670-04

Standard Test Method for Failure End Point in Accelerated and Outdoor Weathering of Bituminous Materials