ASTM D4872-99(2010) - 1.3.2010
 
Significance and Use

Dissipation factor, permittivity and dc volume resistivity are properties of communication cable fillers and filler components that are controlled in order that the cable’electrical performance falls within its design limits. Relatively small amounts of contaminants, such as polar compounds, water or salts, degrade the cable’electrical properties. Limits on the dielectric properties of the cable filling compound are usually specified by the cable manufacturer, by industry standards or both.

 
1. Scope

Dissipation factor, permittivity and dc volume resistivity are properties of communication cable fillers and filler components that are controlled in order that the cable's electrical performance falls within its design limits. Relatively small amounts of contaminants, such as polar compounds, water or salts, degrade the cable's electrical properties. Limits on the dielectric properties of the cable filling compound are usually specified by the cable manufacturer, by industry standards or both.

 
2. Referenced Documents

D150-22

Standard Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation

D1711-26

Standard Terminology Relating to Electrical Insulation

D1321-24a

Standard Test Method for Needle Penetration of Petroleum Waxes (Includes all amendments and changes 1/15/2025).

D6054-97

Standard Practice for Conditioning Electrical Insulating Materials for Testing

D257-14(2021)e1

Standard Test Methods for DC Resistance or Conductance of Insulating Materials (Includes all amendments and changes 5/6/2021).