ASTM D4986-03 - 10.5.2003
 
Significance and Use

This test method provides a means of measuring the time and extent of burning for cellular polymeric materials. It also provides a means of measuring burning rates for materials that continue to burn past the specified gage marks.

This test method provides a means of comparing the burning characteristics of materials of like thickness density, cell size, and skin irregularities, including the effect of falling particles of cellular polymeric materials. It may be used for quality control, specification acceptance, and for research and development. Such materials may be filled or reinforced, rigid or flexible, cut or formed.

In this test method, the specimens are subjected to one or more specific sets of laboratory fire test exposure conditions. If different test conditions are substituted or if the anticipated end-use conditions are changed, it may not be possible from this test method to predict changes in the performance characteristics measured. Therefore, the results are strictly valid only for the fire test exposure conditions described in this procedure.

This test method is not intended to be a criterion for fire hazard. The fire hazard created by materials depends upon the form and end use of the material. Assessment of fire hazard includes, but is not limited to, many factors such as flame spread, burning rate, ease of ignition, fuel contribution, heat evolution, products of combustion, and others.

 
1. Scope

1.1 This fire-test-response test method describes a small-scale horizontally oriented burning test procedure for comparing the relative rate of burning and the extent and time of burning of cellular polymeric materials having a density less than 250 kg/m3.

1.2 The classification system described in the Appendix X1 is intended for quality assurance and the preselection of component materials for products.

1.3 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Note 3.

Note 1—This test method and ISO 9772 are technically equivalent.

 
2. Referenced Documents

E437-92(1997)

Specification for Industrial Wire Cloth and Screens (Square Opening Series) (Withdrawn 2000)

ISO 9772

Cellular Plastics--Determination of Horizontal Burning Characteristics of Small Specimens Subjected to a Small Flame Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http://www.ansi.org.

D4483-25

Standard Practice for Evaluating Precision for Test Method Standards in the Rubber and Carbon Black Manufacturing Industries

E176-24a

Standard Terminology of Fire Standards (Includes all amendments and changes 12/9/2024).

D5025-20a

Standard Specification for Laboratory Burner Used for Small-Scale Burning Tests on Plastic Materials (Includes all amendments and changes 4/16/2020).