ASTM D5060-95(2000) - 10.6.2000
 
1. Scope

1.1 This test method describes the analysis of normally occurring impurities in, and the purity of, ethylbenzene by gas chromatography. Impurities determined include nonaromatic hydrocarbons, benzene, toluene, xylenes, cumene, and diethylbenzene isomers.

1.2 This test method is applicable for impurities at concentrations from 0.001 to 1.000% and for ethylbenzene purities of 99% or higher. At this level, -xylene may not be detected.

1.3 The following applies to all specified limits in this standard: for purposes of determining conformance with this standard, an observed value or a calculated value shall be rounded off "to the nearest unit" in the last right-hand digit used in expressing the specification limit, in accordance with the rounding-off method of Practice E29.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 7.

 
2. Referenced Documents

D6809-24

Standard Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarbons and Related Materials

E355-96(2021)e1

Standard Practice for Gas Chromatography Terms and Relationships (Includes all amendments and changes 4/28/2021).

E29-22

Standard Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications

E1510-95(2021)

Standard Practice for Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs

D4307-17(2021)

Standard Practice for Preparation of Liquid Blends for Use as Analytical Standards

D3437-15(2022)

Standard Practice for Sampling and Handling Liquid Cyclic Products