ASTM D5109-12 - 1.11.2012
 
1. Scope

1.1 These test methods cover the procedures for testing copper-clad laminates produced from fiber-reinforced, thermosetting polymeric materials intended for fabrication of printed wiring boards.

1.2 The procedures appear in the following sections:

Procedure

Section

 Referenced Documents

2

 Conditioning

4

 Dielectric Breakdown Voltage Parallel to Laminations

13

 Dimensional Instability

19

 Dissipation Factor

14

 Flammability Rating Test

16

 Flexural Strength, Flatwise at Elevated Temperature

15

 Flexural Strength, Flatwise at Room Temperature

15

 Oven Blister Test

17

 Peel Strength Test at Elevated Temperature

10

 Peel Strength Test at Room Temperature

9

 Permittivity

14

 Pin Holes in Copper Surface

20

 Purity of Copper

5

 Scratches in Copper Surface

21

 Solder Float Test

8

 Solvent Resistance

7

 Surface Resistivity

11

 Volume Resistivity

11

 Terminology

3

 Thickness & Thickness Variation

18

 Warp or Twist

6

 Water Absorption

12


1.3 Metric units are the preferred units for these test methods. Inch-pound units, where shown, are presented for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.2.1, 8.1, and 11.3.1.

 
2. Referenced Documents

D257-14(2021)e1

Standard Test Methods for DC Resistance or Conductance of Insulating Materials (Includes all amendments and changes 5/6/2021).

D374-99

Standard Test Methods for Thickness of Solid Electrical Insulation

D618-21

Standard Practice for Conditioning Plastics for Testing

D1825-03

Standard Practice for Etching and Cleaning Copper-Clad Electrical Insulating Materials and Thermosetting Laminates for Electrical Testing (Withdrawn 2012)

D150-22

Standard Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation

E53-07

Standard Test Method for Determination of Copper in Unalloyed Copper by Gravimetry

D3636-24

Standard Practice for Sampling and Judging Quality of Solid Electrical Insulating Materials

NEMA Publication Number LI 1-1975

Test for Hot Peel Strength of Copper-Clad Industrial Laminates for Printed Circuits Available from National Electronic Manufacturers Association (NEMA), 2101 L St., NW, Washington, DC 20037.

D1711-26

Standard Terminology Relating to Electrical Insulation

D1867-13

Standard Specification for Copper-Clad Thermosetting Laminates for Printed Wiring (Withdrawn 2020)

D229-26

Standard Test Methods for Rigid Sheet and Plate Materials Used for Electrical Insulation

D1531-06

Standard Test Methods for Relative Permittivity (Dielectric Constant) and Dissipation Factor by Fluid Displacement Procedures (Withdrawn 2012)