ASTM D5316-98 - 10.7.1998
 
1. Scope

1.1 This test method covers the determination of 1,2-dibromoethane (commonly referred to as ethylene dibromide or EDB) and 1,2-dibromo-3-chloropropane (commonly referred to as DBCP) in water at a minimum detection level of 0.010 [mu]g/L by liquid-liquid extraction combined with gas-liquid chromatography. This test method is applicable to the analysis of drinking waters and groundwaters. It is not recommended for wastewaters, due to the potential for interferences from high concentrations of other extractable organics. Similar information can be found in EPA Method 504.

1.2 This test method was used successfully with reagent water and groundwater. It is the user's responsibility to ensure the validity of this test method for waters of untested matrices.

1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Sections 6 and 9.

 
2. Referenced Documents

D1066-18(2025)

Standard Practice for Sampling Steam

D1129-24

Standard Terminology Relating to Water

D1192-98

Standard Guide for Equipment for Sampling Water and Steam in Closed Conduits (Withdrawn 2003)

D1193-24

Standard Specification for Reagent Water

D3370-25

Standard Practices for Sampling Water from Flowing Process Streams

D3856-11

Standard Guide for Management Systems in Laboratories Engaged in Analysis of Water

D4210-89(1996)e1

Standard Practice for Intralaboratory Quality Control Procedures and a Discussion on Reporting Low-Level Data (Withdrawn 2002)

D5789-95

Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Organic Constituents (Withdrawn 2002)