ASTM D5469-00(2005) - 1.5.2005
 
Significance and Use

This guide outlines general procedures and precautions necessary for correct and safe application of spray applied polyurethane foam roofing systems.

This guide is not all-inclusive; this guide is intended only to supplement detailed instructions from manufacturers and safety requirements established by law.

Refer to Polyurethane Foam Contractors Alliance AY-104 and NRCA Spray Polyurethane Foam-Based Manual for industry guidelines.

 
1. Scope

1.1 This guide covers the application of new roofing systems consisting of spray applied polyurethane foam insulation, elastomeric protective coatings, and optional mineral granules. This guide does not apply to retrofit or remedial applications.

1.2 Design criteria associated with the installation of spray in place polyurethane foam are beyond the scope of this specification.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

D1079-26c

Standard Terminology Relating to Roofing and Waterproofing (Includes all amendments and changes 8/25/2026).

D1622-26

Standard Test Method for Apparent Density of Rigid Cellular Plastics

D451-91(1996)e1

Standard Test Method for Sieve Analysis of Granular Mineral Surfacing For Asphalt Roofing Products

D1621-16(2023)

Standard Test Method for Compressive Properties of Rigid Cellular Plastics

NRCA/SPFA Manual for Inspection and Maintenance of Spray Polyurethane Foam-Based Roof Systems,

A Guide for Building Owners

SSPC SP-6

Steel Structures Painting Council Available from Society for Protective Coatings (SSPC), 40 24th St., 6th Floor, Pittsburgh, PA 15222-4656.

D2856-94(1998)

Standard Test Method for Open-Cell Content of Rigid Cellular Plastics by the Air Pycnometer (withdrawn 2006)

D4442-20(2025)

Standard Test Methods for Direct Moisture Content Measurement of Wood and Wood-Based Materials

C1029-25

Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation