ASTM D5485-09 - 1.6.2009
 
Significance and Use

The metal loss from corrosion is directly related to the increase in electrical resistance of the target due to the decrease in conductive cross-sectional area.

The relationship between resistance increase of metallic targets used in this test method and the amount of metal loss as reported by a uniform loss in thickness has not been determined.

This test method is used to determine the corrosive effect of combustion products from burning electrical insulations or coverings or their constituent materials or components. Corrosion is determined by the reduction of thickness of the metal on standardized targets, as measured by electrical resistance. These targets are not necessarily representative of the intended end use.

This test method is intended for use in electrical insulations or coverings material and product evaluations, for additional data to assist in design of electrical insulations or coverings products, or for development and research of electrical insulations or coverings products.

A value of the heating flux is selected to be relevant to the fire scenario being investigated (up to 100 kW/m2). Additional information for testing is given in A1.2.3.

 
1. Scope

1.1 This fire-test-response standard measures the corrosive effect by loss of metal from the combustion products of materials, components, or products.

1.2 This test method provides corrosion results of product and material specimens limited to a maximum size of 100 by 100 mm in area and 50 mm thick.

1.3 The results of this test method have not been investigated with respect to correlation to actual fires.

1.4 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.

1.4.1 Additional information regarding the targets, the test conditions, and test limitations are provided in the annex.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. (See IEEE/ASTM SI-10 )

 
2. Referenced Documents

OSHA 191.1450

Occupational Exposure to Hazard Chemicals in Laboratories Available from Occupational Safety and Health Administration (OSHA)/U.S. Departmnet of Labor, 200 Constitution Ave., NW, Washington, DC 20210, http://www.osha.gov.

D618-21

Standard Practice for Conditioning Plastics for Testing

ISO 11907-4

PlasticsSmoke GenerationDetermination of the Corrosivity of Fire EffluentsPart 4: Dynamic Decomposition Method Using a Conical Radiant Heater

Standard for Use of the International System of Units (SI): The Modern Metric System

E176-24a

Standard Terminology of Fire Standards (Includes all amendments and changes 12/9/2024).

D6113-25

Standard Test Method for Using Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables

D1711-26

Standard Terminology Relating to Electrical Insulation

E1354-26

Standard Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter