ASTM D5516-02 - 10.11.2002
 
1. Scope

1.1 This test method is designed to determine the effect of exposure to high temperatures and humidities on the flexure properties of fire-retardant treated softwood plywood. In this test method, plywood is exposed to a temperature of 77°C (170°F).

1.2 The purpose of the test method is to compare the flexural properties of fire-retardant treated plywood relative to untreated plywood. The results of tests conducted in accordance with this test method provide a reference point for estimating strength temperature relationships. This test method is intended to provide an accelerated test at elevated temperatures and controlled humidities of plywood sheathing treated with the same chemical formulation(s) and processing conditions as plywood used commercially.

1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E176-24a

Standard Terminology of Fire Standards (Includes all amendments and changes 12/9/2024).

E84-26a

Standard Test Method for Surface Burning Characteristics of Building Materials (Includes all amendments and changes 4/15/2026).

D6305-21

Standard Practice for Calculating Bending Strength Design Adjustment Factors for Fire-Retardant-Treated Plywood Roof Sheathing

D3043-17(2025)

Standard Test Methods for Structural Panels in Flexure

D2915-25

Standard Practice for Sampling and Data-Analysis for Structural Wood and Wood-Based Products

D1165-25

Standard Nomenclature of Commercial Hardwoods and Softwoods

PS 2

U.S. Product Standard for Wood-Based Structural Use Panels

D9-20

Standard Terminology Relating to Wood and Wood-Based Products