ASTM D5578-94(1999)e1 - 10.12.1999
 
1. Scope

1.1 This test method covers a method of collecting and analyzing samples to determine the amount of ethylene oxide (ETO) present in workplace atmospheres.

1.2 This test method can be used to provide a time-weighted average (TWA) over the concentration range from 0.2 to 30 ppm.

1.3 This test method can be used to determine 15-min excursions (STEL) ranging from 10 to 500 ppm.

1.4 The values stated in SI units are to be regarded as the standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 9 for specific safety hazards.

 
2. Referenced Documents

D1356-20a

Standard Terminology Relating to Sampling and Analysis of Atmospheres (Includes all amendments and changes 9/7/2020).

E355-96(2021)e1

Standard Practice for Gas Chromatography Terms and Relationships (Includes all amendments and changes 4/28/2021).

Occupational Safety and Health Administration, U.S. Department of Labor, Title 29,

Code of Federal Regulations, Part 1910, Subpart Z, Section 1910.1047

D3686-20

Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)

D3687-19

Standard Test Method for Analysis of Organic Compound Vapors Collected by the Activated Charcoal Tube Adsorption Method