ASTM D56-22 - 1.7.2022
 
Significance and Use

5.1?Flash point measures the tendency of the specimen to form a flammable mixture with air under controlled laboratory conditions. It is only one of a number of properties that shall be considered in assessing the overall flammability hazard of a material.

5.2?Flash point is used in shipping and safety regulations to define flammable and combustible materials. One should consult the particular regulation involved for precise definitions of these classes.

5.3?Flash point can indicate the possible presence of highly volatile and flammable materials in a relatively nonvolatile or nonflammable material. For example, an abnormally low flash point on a sample of kerosene can indicate gasoline contamination.

 
1. Scope

1.1?This test method covers the determination of the flash point, by Tag manual and automated closed testers, of liquids with a viscosity below 5.5 mm2/s (cSt) at 40 ?C (104 ?F), or below 9.5 mm2/s (cSt) at 25 ?C (77 ?F), and a flash point below 93 ?C (200 ?F).

1.1.1?Two sets of test conditions are used within this test method: low temperature (LT) test conditions for expected flash points < 60 ?C, and high temperature (HT) test conditions for expected flash points of ? 60 ?C.

1.1.2?For the closed-cup flash point of liquids with the following properties: a viscosity of 5.5 mm2/s (cSt) or more at 40 ?C (104 ?F); a viscosity of 9.5 mm2/s (cSt) or more at 25 ?C (77 ?F); a flash point of 93 ?C (200 ?F) or higher; a tendency to form a surface film under test conditions; or containing suspended solids, Test Method D93 can be used.

1.1.3?For cut-back asphalts refer to Test Methods D1310 and D3143.

Note 1:?The U.S. Department of Transportation (RSTA)2 and U.S. Department of Labor (OSHA) have established that liquids with a flash point under 37.8 ?C (100 ?F) are flammable as determined by this test method for those liquids that have a viscosity less than 5.5 mm2/s (cSt) at 40 ?C (104 ?F) or 9.5 mm2/s (cSt) or less at 25 ?C (77 ?F), or do not contain suspended solids or do not have a tendency to form a surface film while under test. Other flash point classifications have been established by these departments for liquids using this test method.

1.2?This test method can be used to measure and describe the properties of materials, products, or assemblies in response to heat and flame under controlled laboratory conditions and cannot be used to describe or appraise the fire hazard or fire risk of materials, products, or assemblies under actual fire conditions. However, results of this test method can be used as elements of fire risk assessment that takes into account all of the factors that are pertinent to an assessment of the fire hazard of a particular end use.

1.3?Related standards are Test Methods D93, D1310, D3828, D3278, and D3941.

1.4?The values stated in SI units are to be regarded as standard. The values given in parentheses are for information only.

1.5?WARNINGMercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Use Caution when handling mercury and mercury-containing products. See the applicable product Safety Data Sheet (SDS) for additional information. The potential exists that selling mercury or mercury-containing products, or both, is prohibited by local or national law. Users must determine legality of sales in their location.

1.6?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific warning statements see 6.5, 7.1, 9.3, 11.1.4, and refer to Safety Data Sheets.

1.7?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

D3278-21

Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus

D3828-16a(2021)

Standard Test Methods for Flash Point by Small Scale Closed Cup Tester (Includes all amendments and changes 7/26/2021).

D3941-20

Standard Test Method for Flash Point by the Equilibrium Method With a Closed-Cup Apparatus

D4057-22

Standard Practice for Manual Sampling of Petroleum and Petroleum Products

D6299-26

Standard Practice for Applying Statistical Quality Assurance and Control Charting Techniques to Evaluate Analytical Measurement System Performance

D93-26

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester

D1310-14(2021)

Standard Test Method for Flash Point and Fire Point of Liquids by Tag Open-Cup Apparatus

D3143-08

Standard Test Method for Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus

E502-21a

Standard Test Method for Selection and Use of ASTM Standards for the Determination of Flash Point of Chemicals by Closed Cup Methods (Includes all amendments and changes 7/14/2021).

Method1101,

Federal Test Method Standard No. 791b

Method4291,

Federal Test Method Standard No. 141A

D6300-26

Standard Practice for Determination of Precision and Bias Data for Use in Test Methods for Petroleum Products, Liquid Fuels, and Lubricants

Guide34

Reference materialsGeneral and statistical principles for certification

E1-14(2025)

Standard Specification for ASTM Liquid-in-Glass Thermometers