Significance and Use

Broad-crested weirs can be used for accurate measurements of a wide range of flow rates, but their structural simplicity and sturdiness make them particularly useful for measuring large flows under field conditions.

Because they require vertical sidewalls, broad-crested weirs are particularly adaptable to rectangular artificial channels or to natural and artificial channels that can readily be lined with vertical sidewalls in the immediate vicinity of the weir.

 
1. Scope

1.1 This test method covers measurement of the volumetric flow rate of water in open channels with two types of horizontal broad-crested weirs: those having a square (sharp) upstream corner and those having a well-rounded upstream corner.

1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

ISO 555-1973

Liquid Flow Measurement in Open Channels--Dilution Methods for Measurement of Steady Flow--Constant Rate Injection Method

D3858-95(1999)

Standard Test Method for Open-Channel Flow Measurement of Water by Velocity-Area Method

D2777-21

Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water

D1129-24

Standard Terminology Relating to Water

ISO 4374-1990

Liquid Flow Measurement in Open Channels by Weirs and Flumes--Round-Nose Horizontal Crest Weirs

ISO 3846-1989

Liquid Flow Measurement in Open Channels by Weirs and Flumes--Rectangular Broad-Crested Weirs

ISO 4373-1979

Measurement of Liquid Flow in Open Channels--Water Level Measuring Devices