1. Scope

1.1 This test method covers determination of the operating characteristics of home reverse osmosis devices using standard test conditions. It does not necessarily determine the characteristics of the devices operating on natural waters.

1.2 This test method is applicable for spiral-wound devices.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

D4516-19a

Standard Practice for Standardizing Reverse Osmosis Performance Data (Includes all amendments and changes 11/26/2019).

D6161-19

Standard Terminology Used for Microfiltration, Ultrafiltration, Nanofiltration, and Reverse Osmosis Membrane Processes

D4194-23

Standard Test Methods for Operating Characteristics of Reverse Osmosis and Nanofiltration Devices

D2777-21

Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water

D1293-18

Standard Test Methods for pH of Water

D1193-24

Standard Specification for Reagent Water

D1129-24

Standard Terminology Relating to Water

D1125-23

Standard Test Methods for Electrical Conductivity and Resistivity of Water

D512-23

Standard Test Methods for Chloride Ion In Water