ASTM D6011-96 - 10.10.1996
 
1. Scope

1.1 This test method covers the determination of the dynamic performance of a sonic anemometer/thermometer which employs the inverse time measurement technique for velocity or speed of sound, or both. Performance criteria include (a) acceptance angle, (b) acoustic pathlength, (c) system delay, (d) system delay mismatch, (e) thermal stability range, (f) shadow correction, (g) velocity calibration range, and (h) velocity resolution.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

IEEE/ASTM SI 10

American National Standard for Metric Practice

C384-04(2022)

Standard Test Method for Impedance and Absorption of Acoustical Materials by Impedance Tube Method

D5527-23

Standard Practices for Measuring Surface Wind and Temperature by Acoustic Means

D1356-20a

Standard Terminology Relating to Sampling and Analysis of Atmospheres (Includes all amendments and changes 9/7/2020).