ASTM D6120-97(2002) - 10.4.1997
 
1. Scope

1.1 This test method covers the determination of the electrical resistivity at room temperature of solid cylindrical specimens cored from commercial sized carbon anodes and cathodes. This test method also applies to samples from carbon blocks prepared in a laboratory.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitation prior to use. For specific safety information, see 8.2.3.

 
2. Referenced Documents

C611-21

Standard Test Method for Electrical Resistivity of Manufactured Carbon and Graphite Articles at Room Temperature

D5502-25

Standard Test Method for Apparent Density by Physical Measurements of Manufactured Anode and Cathode Carbon Used by the Aluminum Industry