ASTM D6150-97(2003) - 10.7.2003
 
Significance and Use

The volatile components of a plastisol or organosol influences the weight loss during processing. In addition, this information may be useful to the producer and user and to environmental interests for estimating the volatiles emitted by the plastisol or organosol during processing.

Results obtained by this test method are not strictly equivalent to those experienced during product processing wherein conditions of temperature, air flow, coating mass, and configuration may be quite different.

This test method may not be applicable to all types of plastisol and organosol applications. Any change in the specified testing time or temperature to accommodate unique applications shall be included in the report (see 7.3).

 
1. Scope

1.1 This test method describes a procedure for the determination of the relative volatility of polyvinyl chloride plastisols and organosols at elevated temperatures.

1.2 The values stated in SI units are to be regarded as the standard. The values given in brackets are for information only.

1.3 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 1—There are no ISO standards equivalent to this test method.

 
2. Referenced Documents

D1600-18

Standard Terminology for Abbreviated Terms Relating to Plastics (Withdrawn 2024)

D883-26a

Standard Terminology Relating to Plastics (Includes all amendments and changes 6/15/2026).

E145-19(2024)

Standard Specification for Gravity-Convection and Forced-Ventilation Ovens

D618-21

Standard Practice for Conditioning Plastics for Testing

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E177-26a