ASTM D6714-01(2006) - 1.10.2006
 
Significance and Use

The procedure described is specific for chromium in wet blue. Vanadium is the only common interfering element and this is rarely present in quantity. The precision and accuracy of the methods are usually at least as good as the sampling of the wet blue itself, and the accuracy of previously performed test methods.

The chromium content of wet blue is related to the degree of tannage obtained, and hence may be a matter for specification in the purchase of wet blue. The procedure described provides adequate accuracy for this purpose.

 
1. Scope

1.1 This test method covers the determination of chromic oxide in wet blue that has been partly or completely tanned with chromium compounds. In general the samples will contain chromium content between 1 and 5 %, calculated as chromic oxide expressed upon a dry basis otherwise referred to as moisture-free basis (mfb).

1.2 This test method is specific in that it applies to a sample or samples that are the resultant ash following the execution of Test Method D 6716.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards are given in Section .

 
2. Referenced Documents

D6659-16(2026)

Standard Practice for Sampling and Preparation of Wet Blue and Wet White for Physical and Chemical Tests

D6716-24

Standard Test Method for Total Ash in Wet Blue or Wet White

E180-03

Standard Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals (Withdrawn 2009)

D6658-24

Standard Test Method for Volatile Matter (Moisture) of Wet Blue by Oven Drying