ASTM D6764-02 - 10.3.2002
 
1. Scope

1.1 This guide describes procedures to collect cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of water flowing in open channels.

1.2 This guide provides guidelines for preparation and calibration of the equipment to collect cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of water flowing in open channels.

1.3 This guide describes what equipment should be used to collect cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of water flowing in open channels.

1.4 This guide covers the cross-sectional means of temperature, dissolved oxygen, specific electrical conductance, and pH of fresh water flowing in open channels.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

 
2. Referenced Documents

D4411-03(2019)

Standard Guide for Sampling Fluvial Sediment in Motion

D888-18(2026)

Standard Test Methods for Dissolved Oxygen in Water

D1293-18

Standard Test Methods for pH of Water

D1129-24

Standard Terminology Relating to Water

D1125-23

Standard Test Methods for Electrical Conductivity and Resistivity of Water

D4410-25

Standard Terminology for Fluvial Sediment

D5464-25

Standard Test Method for pH Measurement of Water of Low Conductivity