ASTM D6791-22 - 1.5.2022
 
Significance and Use

5.1?The grain stability of calcined petroleum coke determines the resistance to breakdown of + 4 mm particles used in the manufacture of carbon anodes for use in the reduction process of aluminum.

5.2?Calcined petroleum cokes have to be relatively easy to grind for fines production but strong enough to withstand forming pressures and thermal stresses occurring when the anodes are used in the reduction process.

 
1. Scope

1.1?This test method covers a laboratory vibration mill method for the determination of the grain stability of calcined petroleum coke for the manufacture of carbon products used in the smelting of aluminum. Calcined petroleum coke with poor mechanical strength may become degraded during mixing. Poor grain stability will affect the grain size and may result in poor quality of baked blocks.

1.2?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

D6969-23

Standard Practice for Preparation of Calcined Petroleum Coke Samples for Analysis

D2234/D2234M-20

Standard Practice for Collection of a Gross Sample of Coal

D2013-07

Standard Practice for Preparing Coal Samples for Analysis

D346-25

Standard Practice for Collection and Preparation of Coke Samples for Laboratory Analysis

ISO 6375

Carbonaceous Materials for the Production of AluminumCoke for ElectrodesSampling

E11-24

Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves

D6970-24

Standard Practice for Collection of Calcined Petroleum Coke Samples for Analysis