ASTM D7650-21 - 1.12.2021
 
Significance and Use

5.1?This sampling procedure is used to collect a particulate filter sample containing particulates 0.2 ?m or larger in size to be used to measure the size and concentration of particulates in a gaseous fuel stream.

 
1. Scope

1.1?This practice is primarily for sampling particulates in gaseous fuels up to a nominal working pressure (NWP) of 70 MPa (10 152 psi) using an in-stream filter. This practice describes sampling apparatus design, operating procedures, and quality control procedures required to obtain the stated levels of precision and accuracy.

1.2?UnitsThe values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.

1.3?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

SAE J2719

Hydrogen Fuel Quality for Fuel Cell Vehicles

API 598

Valve Inspection and Testing

SAE J2600

Compressed Hydrogen Surface Vehicle Refueling Connection Devices

ISO/CD 14687–2

Hydrogen fuel -- Product Specification -- Part 2: Proton exchange membrane (PEM) fuel cell applications for road vehicles.

D7651-24e1

Standard Test Method for Gravimetric Measurement of Particulate Concentration of Hydrogen Fuel (Includes all amendments and changes 7/3/2024).

97/23/EC

Pressure Equipment Directive of the EU set out the standards for the design and fabrication of pressure equipment