ASTM E799-03(2015) - 1.3.2015
 
Significance and Use

4.1 These criteria6 and procedures provide a uniform base for analysis of liquid drop data.

 
1. Scope

1.1 This practice gives procedures for determining appropriate sample size, size class widths, characteristic drop sizes, and dispersion measure of drop size distribution. The accuracy of and correction procedures for measurements of drops using particular equipment are not part of this practice. Attention is drawn to the types of sampling (spatial, flux-sensitive, or neither) with a note on conversion required (methods not specified). The data are assumed to be counts by drop size. The drop size is assumed to be the diameter of a sphere of equivalent volume.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 The analysis applies to all liquid drop distributions except where specific restrictions are stated.

 
2. Referenced Documents

9272–2

Calculation of Average Particle Sizes/Diameters and Moments from Particle Size Distribution

9276–1

Representation of Results of Particle Size Analysis-Graphical Representation

13320–1

Particle Size Analysis-Laser Diffraction Methods

E1296-92

Terminology Relating to Liquid Particle Statistics (Withdrawn 1997)