ASTM F1277-95 - 1.1.1995
 
1. Scope

1.1 This test method provides for the measurement of chloride ion leached from flexible graphite, asbestos, or paper-based packing and gasketing materials. Samples containing 7 to 6700 [mu]g Cl /g sample can be analyzed with this procedure. The upper concentration limit can be extended by dilution of the test solution.

1.2 It is the responsibility of the analyst to ensure the validity of this test method for other packing or gasketing materials.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific warning statement is given in 7.3.

 
2. Referenced Documents

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E50-17

Standard Practices for Apparatus, Reagents, and Safety Considerations for Chemical Analysis of Metals, Ores, and Related Materials

D512-23

Standard Test Methods for Chloride Ion In Water

E882-10(2016)e1

Standard Guide for Accountability and Quality Control in the Chemical Analysis Laboratory (Includes all amendments and changes 10/27/2017).