ASTM F1606-95 - 1.1.1995
 
1. Scope

1.1 This practice covers the requirements for the installation of deformed polyethylene (PE) liner for pipeline rehabilitation.

1.2 This practice describes a method by which the PE liner may be installed with little or no excavation.

1.3 This practice applies to the rehabilitation of 3 to 18- in. (76 to 457-mm) diameter pipe in terms of installation. The specifier determines what DR is used based on conditions of the specific application.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

D1600-18

Standard Terminology for Abbreviated Terms Relating to Plastics (Withdrawn 2024)

D2122-22

Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings

D3350-21

Standard Specification for Polyethylene Plastics Pipe and Fittings Materials

D638-22

Standard Test Method for Tensile Properties of Plastics

D790-17

Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials

Recommended Specifications for Sewer Collection System Rehabilitation NASSCO, Inc. 2470 Longstone Lane, Suite M, Marriottsville, MD 21104. http://nassco.org/

F412-23

Standard Terminology Relating to Plastic Piping Systems

F1533-20

Standard Specification for Deformed Polyethylene (PE) Liner

F1417-11A(2019)e1

Standard Practice for Installation Acceptance of Plastic Non-pressure Sewer Lines Using Low-Pressure Air (Includes all amendments and changes 5/13/2020).