ASTM F1867-06(2020) - 15.11.2020
 
Significance and Use

4.1?This practice is for use by designers, and specifies regulatory agencies, owners, and inspection organizations involved in the rehabilitation of non-pressure sewers and conduits. Modifications may be required, depending on specific job conditions, to establish a project specification. The manufacturer of the product should be consulted for design and installation information. Industrial waste disposal lines should be installed only with the specific approval of the cognizant code authority, since chemicals not commonly found in drains and sewers and temperatures in excess of 140 ?F (60 ?C) may be encountered.

 
1. Scope

1.1?This practice covers the procedures for the rehabilitation of sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm) in diameter by the insertion of a folded/formed PVC pipe that is heated, pressurized, and expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe. This rehabilitation process can be used in a variety of gravity applications such as sanitary sewers, storm sewers, and process piping.

1.2?This practice is to be used with the material specified in Section 6 of Specification F1871.

1.3?The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4?There is no similar or equivalent ISO Standard.

1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

F1871-24

Standard Specification for Folded/Formed Poly-(Vinyl Chloride) Pipe Type A for Existing Sewer and Conduit Rehabilitation

D638-22

Standard Test Method for Tensile Properties of Plastics

UNI-B-5-89

Recommended Practice for the Installation of Polyvinyl Chloride (PVC) Sewer Pipe Available from Uni-Bell PVC Pipe Association, 2711 LBJ Freeway, Suite 1000, Dallas, TX 75234, http://www.uni-bell.org.

D648-18

Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in the Edgewise Position

D790-17

Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials

D1600-18

Standard Terminology for Abbreviated Terms Relating to Plastics (Withdrawn 2024)

D1784-20

Standard Classification System and Basis for Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds

D2122-22

Standard Test Method for Determining Dimensions of Thermoplastic Pipe and Fittings

F412-23

Standard Terminology Relating to Plastic Piping Systems

F1417-11A(2019)e1

Standard Practice for Installation Acceptance of Plastic Non-pressure Sewer Lines Using Low-Pressure Air (Includes all amendments and changes 5/13/2020).