ASTM F1883-03 - 10.5.2003
 
Significance and Use

The selection criteria is to be applied for uses of (1) new cable and (2) replacement cable.

For the selection of new cable or the selection of replacement cable, this practice defines the choice criteria for conductor selection for cables in AWG (ASTM) or metric (IEC) sizes.

 
1. Scope

1.1 This practice is intended as a guide to shipbuilders, shipowners, and design agents for use in the selection of conductor size for single conductor or multiple conductor cable sizes either in American Wire Gauge (AWG) or metric designations for commercial ship design and construction.

1.2 The comparison chart of electrical conductor sizes shown in Table 1 presents a combined listing of international standard sizes of annealed copper conductors in accordance with AWG (Specification B 8) English units or IEC (IEC 228) metric units.

1.3 As a precautionary caveat, some conductor sizes listed in Table 1 may exceed minimal size requirements of the U.S. Coast Guard, the American Bureau of Shipping, and IEEE STD 45 for specific applications

1.4 The values stated for ampacity and dc resistance are presented as typical values and are provided for information only.

 
2. Referenced Documents

IEC 60092-350

Electrical Installations in Ships--Part 350: Shipboard Power: Cables--General Construction and Test Requirements

IEC 60228

Conductors of Insulated Cables

B8-23

Standard Specification for Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft

IEEE STD 45

Recommended Practice for Electric Installations on Shipboard

B193-20

Standard Test Method for Resistivity of Electrical Conductor Materials