| ASTM B77-07 - 1.5.2007 | ||
| Significance and Use | ||
The purpose of this method is to determine the suitability of different metals for use in resistance apparatus in which a low thermoelectric power is desired. As most electric circuits are largely composed of copper, the thermoelectric power of a resistance metal will generally be measured against copper. | ||
| 1. Scope | ||
1.1 This test method covers the determination of the thermoelectric power of a metal or alloy with respect to copper when the temperatures of the junctions lie between 0 and 100C. 1.2 The values stated in inch-pound units are the preferred unit. The values in parentheses are for information only. | ||
| 2. Referenced Documents | ||
|