ASTM B8-99 - 10.4.1999
 
1. Scope

1.1 This specification covers bare concentric-lay-stranded conductors made from round copper wires, either uncoated or coated with tin, lead, or lead alloy for general use for electrical purposes. These conductors shall be constructed with a central core surrounded by one or more layers of helically laid wires.

Note 1-This specification also permits conductors for use as covered or insulated electrical conductors. Note 2-Sealed conductors, that are intended to prevent longitudinal water propagation and are further covered/insulated, are also permitted within the guidelines of this specification.

1.2 For the purposes of this specification, conductors are classified as follows (Explanatory Notes 1 and 2):

1.2.1 Class AA -For bare conductors usually used in overhead lines.

1.2.2 Class A -For conductors to be covered with weather-resistant (weather-proof), slow-burning, materials, and for bare conductors where greater flexibility than is afforded by Class AA is required.

1.2.3 Class B -For conductors to be insulated with various materials such as rubber, paper, varnished cloth, etc., and for the conductors indicated under Class A where greater flexibility is required.

1.2.4 Class C and Class D -For conductors where greater flexibility is required than is provided by Class B conductors.

1.3 The SI values for density are regarded as the standard. For all other properties, the inch-pound values are to be regarded as standard and the SI units may be approximate.

 
2. Referenced Documents

B1-13(2026)

Standard Specification for Hard-Drawn Copper Wire

B2-13(2026)

Standard Specification for Medium-Hard-Drawn Copper Wire

B3-13(2024)

Standard Specification for Soft or Annealed Copper Wire

B33-10(2020)e1

Standard Specification for Tin-Coated Soft or Annealed Copper Wire for Electrical Purposes (Includes all amendments and changes 1/20/2020).

B172-17(2024)

Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electrical Conductors

B173-17(2024)

Standard Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors

B174-17(2024)

Standard Specification for Bunch-Stranded Copper Conductors for Electrical Conductors

B189-05(2021)

Standard Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for Electrical Purposes

B193-25

Standard Test Method for Resistivity of Electrical Conductor Materials

B246-15(2021)

Standard Specification for Tinned Hard-Drawn and Medium-Hard-Drawn Copper Wire for Electrical Purposes

B263-04

Standard Test Method for Determination of Cross-Sectional Area of Stranded Conductors

B354-23

Standard Terminology Relating to Uninsulated Metallic Electrical Conductors

B787/B787M-04(2020)

Standard Specification for 19 Wire Combination Unilay-Stranded Copper Conductors for Subsequent Insulation