ASTM C1090-01(2005)e1 - 10.6.2005
 
1. Scope

1.1 This test method covers measurement of the changes in height of hydraulic-cement grout by the use of 75 by 150-mm (3 by 6-in.) cylinders, when the cylinders are protected so that the tendency to change in height does not include evaporation so as to cause drying, uptake of moisture, carbonation, or exposure to temperatures outside the range 23 ± 2.0 C (73 ± 3 F) or, optionally, to another specified temperature controlled within ± 2.0 C (± 3 F).

1.2 If desired, this test method can be adapted to studies of changes in height involving either schedules or environmental treatment different from the standard procedures prescribed by this test method.

1.3 The values stated in SI units are to be regarded as the standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

C125-26

Standard Terminology Relating to Concrete and Concrete Aggregates

C172-08

Standard Practice for Sampling Freshly Mixed Concrete

C219-25

Standard Terminology Relating to Hydraulic and Other Inorganic Cements

C305-20

Standard Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency

C511-21

Standard Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes

C670-24ae1

Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials (Includes all amendments and changes 2/21/2025).

C827-01a

Standard Test Method for Change in Height at Early Ages of Cylindrical Specimens of Cementitious Mixtures

C939-10

Standard Test Method for Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method)