ASTM C1127-01(2009) - 1.1.2009
 
Significance and Use

This guide is divided into two sections which provide design and specification guidelines for the use of a cold liquid-applied elastomeric membrane with integral wearing surface for waterproofing building decks in building areas to be occupied by personnel, vehicles, or equipment.

The intent of Sections 5-11, Design Considerations, is to provide information and design guidelines where a waterproofing membrane with integral wearing surface is to be used. The intent of the remaining sections is to provide minimum guide specifications for the use of the purchaser and the seller in contract documents.

Where the state of the art is such that criteria for a particular condition is not as yet firmly established or has numerous variables that require consideration, reference is made to the applicable portion of Sections 5-11 that covers the particular area of concern. Section 16 describes the repair, rehabilitation, and replacement of the membrane.

DESIGN CONSIDERATIONS

Top

 
1. Scope

1.1 This guide describes the design and installation of cold liquid-applied elastomeric waterproofing membrane systems that have an integral wearing surface. The cold liquid-applied elastomeric waterproofing membrane (membrane) to which this guide refers is specified in Specification C 957.

1.2 Concrete Slab-on-Grade—Waterproofing the upper surface of a concrete slab on grade presents special problems due to the possibility of negative hydrostatic pressure causing loss of bond to the substrate. Consideration of these problems is beyond the scope of this guide. Consult the membrane manufacturer for recommendations when this situation exists.

1.3 The committee having jurisdiction for this guide is not aware of any similar ISO standard.

1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements see Note in 15.4.

 
2. Referenced Documents

C33-07

Standard Specification for Concrete Aggregates

C330-05

Standard Specification for Lightweight Aggregates for Structural Concrete

C332-23

Standard Specification for Lightweight Aggregates for Insulating Concrete

C717-26

Standard Terminology of Building Seals and Sealants

C755-25

Standard Guide for Selection of Water Vapor Retarders for Thermal Insulation

C920-18(2024)

Standard Specification for Elastomeric Joint Sealants

C962-88e1

Guide for Use of Elastomeric Joint Sealants

C1193-25

Standard Guide for Use of Joint Sealants

D653-26a

Standard Terminology Relating to Soil, Rock, and Contained Fluids (Includes all amendments and changes 6/15/2026).

D1752-18(2023)

Standard Specification for Preformed Sponge Rubber, Cork, and Recycled PVC Expansion Joint Fillers for Concrete Paving and Structural Construction

D2628-25

Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements

Product Standard PS 1-74

Construction and Industrial Plywood Available from National Institute of Standards and Technology (NIST), 100 Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http://www.nist.gov.

301-84

(1985) Specification for Structural Concrete for Buildings Available from American Concrete Institute (ACI), P.O. Box 9094, Farmington Hills, MI 48333-9094, http://www.concrete.org.

Steel Structures Painting Manual,

Systems and Specifications:

Specification SSPC SP-2

Wire Brush Cleaning Available from Society for Protective Coatings (SSPC), 40 24th St., 6th Floor, Pittsburgh, PA 15222-4656, http://www.sspc.org.

Specification SSPC SP-6

Commercial Blast Cleaning

APA

Plywood Construction Guide Available from American Plywood Assoc. (Forest Industries), P.O. Box 11700, Tacoma, WA?98411.

C957-06

Standard Specification for High-Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane With Integral Wearing Surface

C150-07