| ASTM C118-11 - 1.9.2011 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This specification covers nonreinforced concrete pipe to be used for the conveyance of irrigation water with working pressures, including hydraulic transients, as shown in Table 1 and for use in drainage. 1.2 A complete SI companion to Specification C118 has been developed Note 1—This specification is for manufacturing and purchase only and does not include requirements for bedding, backfill, installation, or field repairs. The owner is cautioned that he must correlate field conditions with the characteristics of the pipe specified and provide inspection during installation. TABLE 1 Standard Dimensions, Working Pressure, and Test Requirements for Standard Concrete Irrigation PipeA 6 7/8 30 50 1300 8 1 30 50 1350 10 11/8 30 50 1400 12 1¼ 25 45 1500 14 13/8 25 45 1600 15 1½ 25 45 1650 16 1½ 25 45 1700 18 1¾ 25 45 1800 20 2 25 40 1850 21 21/8 25 40 1900 24 2¼ 25 40 2000 A For hydrostatic test requirements, refer to 10.5. B Higher working pressures are not prohibited up to a maximum of 40 ft for 6 through 8-in. diameters, 35 ft for 10 through 12-in. diameters, and 30 ft. for 14-in. through 24-in. diameters. In these cases, the strength of the pipe shall be increased to give a minimum of at least four times the design working pressure when tested as specified in 10.5. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||