ASTM C1216-03 - 10.5.2003
 
Significance and Use

The failure of a building sealant in a joint that experiences movement is manifested by cohesive failure in the sealant or adhesive failure between the sealant and substrate, or both. This test method evaluates the performance of one-part elastomeric solvent release sealants in joints subjected to movement and temperature aging.

 
1. Scope

1.1 This test method is a laboratory procedure that determines the adhesion and cohesion performance of one-part elastomeric, solvent release sealants at high and low temperatures by the extension and compression of test specimens.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3 The subcommittee with jurisdiction is not aware of any similar ISO standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see Note 2.

 
2. Referenced Documents

C150-07

Standard Specification for Portland Cement

C33-07

Standard Specification for Concrete Aggregates

DAF-45

Designation System for Aluminum Finishes Available from Aluminum Association, 900 19th St. NW, Washington, DC 20006.

C717-26

Standard Terminology of Building Seals and Sealants

C109/C109M-26a

Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 50 mm [2 in.] Cube Specimens) (Includes all amendments and changes 7/30/2026).