ASTM C1244M-11 - 1.10.2005
 
1. Scope

1.1 This test method covers procedures for testing precast concrete manhole sections when using the vacuum test method to demonstrate the integrity of the installed materials and the construction procedures. This test method is used for testing concrete manhole sections utilizing mortar, mastic, or gasketed joints.

1.2 This test method is intended to be used as a preliminary test to enable the installer to demonstrate the condition of the concrete manholes prior to backfill.

1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

1.3 This test method is the companion to inch-pound Test Method C 1244.

Note 1

Vacuum test criteria presented in this test method are similar to those in general use. The test and criteria have been widely and successfully used in testing manholes.

Note 2

It should be understood that no correlation has been found between vacuum (air) and hydrostatic tests.

 
2. Referenced Documents

C822-21

Standard Terminology Relating to Concrete Pipe and Related Products

C969-24

Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines and Manholes

C1244-11

Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Prior to Backfill

C924-02

Standard Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test Method