ASTM C1260-14 - 1.8.2014
 
Significance and Use

4.1 This test method provides a means of detecting the potential of an aggregate intended for use in concrete for undergoing alkali-silica reaction resulting in potentially deleterious internal expansion. It is based on the NBRI Accelerated Test Method (1-4).3 It is especially useful for aggregates that react slowly or produce expansion late in the reaction. However, it does not evaluate combinations of aggregates with cementitious materials nor are the test conditions representative of those encountered by concrete in service.

4.2 Because the specimens are exposed to a NaOH solution, the alkali content of the cement is not a significant factor in affecting expansions.

4.3 When excessive expansions (see Appendix X1) are observed, it is recommended that supplementary information be developed to confirm that the expansion is actually due to alkali-silica reaction. Sources of such supplementary information include: (1) petrographic examination of the aggregate (Guide C295/C295M) to determine if known reactive constituents are present; (2) examination of the specimens after tests (Practice C856) to identify the products of alkali reaction; and (3) where available, field service records can be used in the assessment of performance.

4.4 When it has been concluded from the results of tests performed using this test method and supplementary information that a given aggregate should be considered potentially deleteriously reactive, the use of mitigative measures such as low-alkali portland cement, mineral admixtures, or ground granulated blast-furnace slag should be evaluated (see last sentence of 4.1).

 
1. Scope

1.1 This test method permits detection, within 16 days, of the potential for deleterious alkali-silica reaction of aggregate in mortar bars.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. When this test method refers to combined-unit standards, the selection of the measurement systems is at the user’s discretion.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. A specific precautionary statement is given in the section on Reagents.

 
2. Referenced Documents

C150/C150M-24

Standard Specification for Portland Cement

C151/C151M-23

Standard Test Method for Autoclave Expansion of Hydraulic Cement

C295/C295M-19

Standard Guide for Petrographic Examination of Aggregates for Concrete

C305-20

Standard Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic Consistency

C490/C490M-21

Standard Practice for Use of Apparatus for the Determination of Length Change of Hardened Cement Paste, Mortar, and Concrete

C511-21

Standard Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of Hydraulic Cements and Concretes

C128-25

Standard Test Method for Relative Density (Specific Gravity) and Absorption of Fine Aggregate

C127-25

Standard Test Method for Relative Density (Specific Gravity) and Absorption of Coarse Aggregate

C125-26

Standard Terminology Relating to Concrete and Concrete Aggregates

C109/C109M-26a

Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 50 mm [2 in.] Cube Specimens) (Includes all amendments and changes 7/30/2026).

D1193-24

Standard Specification for Reagent Water

C670-24ae1

Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials (Includes all amendments and changes 2/21/2025).

C856-18

Standard Practice for Petrographic Examination of Hardened Concrete

E11-24

Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves