ASTM C1287-10 - 1.6.2010
 
1. Scope

1.1 This test method covers the determination of 67 elements in uranium dioxide samples and nuclear grade uranium compounds and solutions without matrix separation by inductively coupled plasma mass spectrometry (ICP-MS). The elements are listed in Table 1. These elements can also be determined in uranyl nitrate hexahydrate (UNH), uranium hexafluoride (UF6), triuranium octoxide (U3O8) and uranium trioxide (UO3) if these compounds are treated and converted to the same uranium concentration solution.

1.2 The elements boron, sodium, silicon, phosphorus, potassium, calcium and iron can be determined using different techniques. The analyst's instrumentation will determine which procedure is chosen for the analysis.

1.3 The test method for technetium-99 is given in Annex A1.

1.4 The values stated in SI units are to be regarded as standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. WarningThe ICP-MS is a source of intense ultra-violet radiation from the radio frequency induced plasma. Protection from radio frequency radiation and UV radiation is provided by the instrument under normal operation.

 
2. Referenced Documents

C776-17(2022)

Standard Specification for Sintered Uranium Dioxide Pellets for Light Water Reactors

C753-16a(2021)

Standard Specification for Nuclear-Grade, Sinterable Uranium Dioxide Powder (Includes all amendments and changes 10/22/2021).

C787-20(2025)

Standard Specification for Uranium Hexafluoride for Enrichment

C788-03(2021)

Standard Specification for Nuclear-Grade Uranyl Nitrate Solution or Crystals

C967-25

Standard Specification for Uranium Ore Concentrate

C996-20(2025)

Standard Specification for Uranium Hexafluoride Enriched to Less Than 5 % 235U

C1346-19

Standard Practice for Dissolution of UF6 from P-10 Tubes

C1347-08(2023)

Standard Practice for Preparation and Dissolution of Uranium Materials for Analysis

D1193-24

Standard Specification for Reagent Water