ASTM C1291-00a - 10.10.2000
 
1. Scope

1.1 This test method covers the determination of tensile creep strain, creep strain rate, and creep time-to-failure for advanced monolithic ceramics at elevated temperatures, typically between 1073 and 2073 K. A variety of specimen geometries are included. The creep strain at a fixed temperature is evaluated from direct measurements of the gage length extension over the time of the test. The minimum creep strain rate, which may be invariant with time, is evaluated as a function of temperature and applied stress. Creep time-to-failure is also included in this test method.

1.2 This test method is for use with advanced ceramics that behave as macroscopically isotropic, homogeneous, continuous materials. While this test method is intended for use on monolithic ceramics, whisker- or particle-reinforced composite ceramics as well as low-volume-fraction discontinuous fiber-reinforced composite ceramics may also meet these macroscopic behavior assumptions. Continuous fiber-reinforced ceramic composites (CFCCs) do not behave as macroscopically isotropic, homogeneous, continuous materials, and application of this test method to these materials is not recommended.

1.3 The values in SI units are to be regarded as the standard (see Practice E380).

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

C1145-19(2025)e1

Standard Terminology of Advanced Ceramics (Includes all amendments and changes 2/20/2025).

E6-25

Standard Terminology Relating to Methods of Mechanical Testing

E220-25

Standard Test Method for Calibration of Thermocouples by Comparison Techniques

E230-03

Standard Specification and Temperature-Electromotive Force (EMF) Tables for Standardized Thermocouples

E639-78(2002)

Standard Test Method for Measuring Total-Radiance Temperature of Heated Surfaces Using a Radiation Pyrometer (Withdrawn 2011)

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E1012-19

Standard Practice for Verification of Testing Frame and Specimen Alignment Under Tensile and Compressive Axial Force Application

IEEE/ASTM SI 10

American National Standard for Use of the International System of Units (SI): The Modern Metric System

E4-24

Standard Practices for Force Calibration and Verification of Testing Machines

E83-25

Standard Practice for Calibration, Verification, and Classification of Extensometer Systems

C1273-18(2024)

Standard Test Method for Tensile Strength of Monolithic Advanced Ceramics at Ambient Temperatures

E139-24

Standard Test Methods for Conducting Creep, Creep-Rupture, and Stress-Rupture Tests of Metallic Materials

E177-26a

Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods (Includes all amendments and changes 5/14/2026).