ASTM C1303-07 - 15.2.2007
 
1. Scope

1.1 This test method covers a procedure for predicting the long-term thermal resistance (LTTR) of unfaced or permeably faced rigid gas-filled closed-cell foam insulations by reducing the specimen thickness to accelerate aging under controlled laboratory conditions () .

1.2 Rigid gas-filled closed-cell foam insulation includes all cellular plastic insulations manufactured with the intent to retain a blowing agent other than air.

1.3 This test method is limited to unfaced or permeably faced, homogeneous materials. This method is applied to a wide range of rigid closed-cell foam insulation types, including but not limited to: extruded polystyrene, polyurethane, polyisocyanurate, and phenolic. This test method does not apply to impermeably faced rigid closed-cell foams or to rigid closed-cell bun stock foams.

Note 1

See Note 0 for more details regarding the applicability of this test method to rigid closed-cell bun stock foams.

1.4 This test method utilizes referenced standard test procedures for measuring thermal resistance. Periodic measurements are performed on specimens to observe the effects of aging. Specimens of reduced thickness (that is, thin slices) are used to shorten the time required for these observations. The results of these measurements are used to predict the long-term thermal resistance of the material.

1.5 The test method is given in two parts. The Prescriptive Method in Part A provides long-term thermal resistance values on a consistent basis that can be used for a variety of purposes, including product evaluation, specifications, or product comparisons. The Research Method in part B provides a general relationship between thermal conductivity, age, and product thickness.

1.5.1 To use the Prescriptive Method, the date of manufacture must be known, which usually involves the cooperation of the manufacturer.

1.6 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

C1126-24

Standard Specification for Faced or Unfaced Rigid Cellular Phenolic Thermal Insulation

C1045-19

Standard Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions

Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation

CAN/ULC S770

Standard Test Method for Determination of Long-Term Thermal Resistance of Closed-Cell Thermal Insulation Foams

E122-17(2022)

Standard Practice for Calculating Sample Size to Estimate, With Specified Precision, the Average for a Characteristic of a Lot or Process

D6226-21

Standard Test Method for Open Cell Content of Rigid Cellular Plastics

D1622-26

Standard Test Method for Apparent Density of Rigid Cellular Plastics

C518-21

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

C578-23

Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation

C591-22

Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation

C1029-25

Standard Specification for Spray-Applied Rigid Cellular Polyurethane Thermal Insulation

C168-25

Standard Terminology Relating to Thermal Insulation

C1289-26

Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board

C177-19e1

Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus (Includes all amendments and changes 2/23/2023).