ASTM C1345-08 - 1.1.2008
 
Significance and Use

This test method measures the presence of uranium and thorium in soil that occurs naturally and as a result of contamination from nuclear operations and uranium ore processing. The reporting detection levels (RDLs) of total uranium and thorium are well below the normal background in soil. The normal background level for uranium is between 3 and 5 μg/g in most geographic areas and slightly higher for thorium. The 235U enrichment is also measured from an initial sample pass through the instrument. The other less abundant uranium isotopes (234U and 236U) are measured down to a typical soil background level after sample concentration and a second sample analysis. This allows for calculation of individual isotopic uranium and total uranium activity. The majority of the uranium activity results from 234U and 238U.

 
1. Scope

1.1 This test method covers the measurement of total uranium (U) and thorium (Th) concentrations in soils, as well as the determination of the isotopic weight percentages of 234U, 235U, 236U, and 238U, thereby allowing for the calculation of individual isotopic uranium activity or total uranium activity. This inductively coupled plasma-mass spectroscopy (ICP-MS) method is intended as an alternative analysis to methods such as alpha spectroscopy or thermal ionization mass spectroscopy (TIMS). Also, while this test method covers only those isotopes listed above, the instrumental technique may be expanded to cover other long-lived radioisotopes since the preparation technique includes the preconcentration of the actinide series of elements. The resultant sample volume can be further reduced for introduction into the ICP-MS via an electrothermal vaporization (ETV) unit or other sample introduction device, even though the standard peristaltic pump introduction is applied for this test method. The sample preparation removes organics and silica from the soil by use of a high temperature furnace and hydrofluoric acid digestion. Thus, this test method can allow for sample variability of both organic and silica content. This test method is also described in ASTM STP 1291. Since this test method using quadrupole ICP-MS was approved, advances have been made in ICP-MS technology in terms of improved sensitivity and lower instrument background as well as the use of collision or reaction cells (or both) and sector field mass spectrometers with single and multiple detectors. These advances should allow this test method to be performed more effectively but it is the user’s responsibility to verify performance.

1.2 The analysis is performed after an initial drying and grinding sample preparation process, and the results are reported on a dry weight basis. The sample preparation technique used incorporates into the sample any rocks and organic material present in the soil. The method of sample preparation applied differs from other techniques, such as those found in Practice C 999, which involve simply tumbling and sieving the sample; however, the user may select whichever technique is most appropriate to their needs.

1.3 The values stated in SI units are to be regarded as standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

D2216-19

Standard Test Methods for Laboratory Determination of Water (Moisture) Content of Soil and Rock by Mass

D3550-01

Standard Practice for Thick Wall, Ring-Lined, Split Barrel, Drive Sampling of Soils

E135-26a

Standard Terminology Relating to Analytical Chemistry for Metals, Ores, and Related Materials (Includes all amendments and changes 8/6/2026).

E305-21

Standard Practice for Establishing and Controlling Spark Atomic Emission Spectrochemical Analytical Curves

E456-13a(2022)e1

Standard Terminology Relating to Quality and Statistics (Includes all amendments and changes 4/16/2024).

E876-89(1994)e1

Standard Practice for Use of Statistics in the Evaluation of Spectrometric Data (Withdrawn 2003)

E882-10

Standard Guide for Accountability and Quality Control in the Chemical Analysis Laboratory

STP 1291

Applications of Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) to Radionuclide Determinations

Method 6020

SW-846, Inductively Coupled Plasma-Mass Spectrometry

C859-26

Standard Terminology Relating to Nuclear Materials

C998-26

Standard Practice for Sampling Surface Soil for Radionuclides

C999-26

Standard Practice for Soil Sample Preparation for the Determination of Radionuclides

C1255-26

Standard Test Method for Analysis of Uranium and Thorium in Soils by Energy Dispersive X-Ray Fluorescence Spectroscopy

D420-18

Standard Guide for Site Characterization for Engineering Design and Construction Purposes

D1193-24

Standard Specification for Reagent Water

D1452-09

Standard Practice for Soil Exploration and Sampling by Auger Borings

D1586-11

Standard Test Method for Standard Penetration Test (SPT) and Split-Barrel Sampling of Soils

D1587-08

Standard Practice for Thin-Walled Tube Sampling of Soils for Geotechnical Purposes

D2113-14

Standard Practice for Rock Core Drilling and Sampling of Rock for Site Exploration (Withdrawn 2023)