ASTM C1421-09 - 1.5.2009
 
Significance and Use

Fracture toughness, KIc, is a measure of the resistance to crack extension in a brittle material. These test methods may be used for material development, material comparison, quality assessment, and characterization.

The pb and the vb fracture toughness values provide information on the fracture resistance of advanced ceramics containing large sharp cracks, while the sc fracture toughness value provides this information for small cracks comparable in size to natural fracture sources. Cracks of different sizes may be used for the sc method. If the fracture toughness values vary as a function of the crack size it can be expected that KIsc will differ from KIpb and KIvb.

 
1. Scope

1.1 These test methods cover the fracture toughness, KIc, determination of advanced ceramics at ambient temperature. The methods determine KIpb (precracked beam test specimen), KIsc (surface crack in flexure), and KIvb (chevron-notched beam test specimen). The fracture toughness values are determined using beam test specimens with a sharp crack. The crack is either a straight-through crack formed via bridge flexure (pb), or a semi-elliptical surface crack formed via Knoop indentation (sc), or it is formed and propagated in a chevron notch (vb), as shown in Fig. 1.

Note 1—The terms bend(ing) and flexure are synonymous in these test methods.

1.2 These test methods are applicable to materials with either flat or with rising R-curves. Differences in test procedure and analysis may cause the values from each test method to be different. For many materials, such as the silicon nitride Standard Reference Material 2100, the three methods give identical results at room temperature in ambient air.

1.3 The fracture toughness values for a material can be functions of environment, test rate and temperature. These test methods give fracture toughness values for specific conditions of environment, test rate and temperature.

1.4 These test methods are intended primarily for use with advanced ceramics which are macroscopically homogeneous. Certain whisker- or particle-reinforced ceramics may also meet the macroscopic behavior assumptions. Single crystals may also be tested.

1.5 This standard begins with a main body that provides information on fracture toughness testing in general. It is followed by annexes and appendices with specific information for the particular test methods.

Main Body

Section

Scope

1

Referenced Documents

2

Terminology (including definitions, orientation and symbols)

3

Summary of Test Methods

4

Significance and Use

5

Interferences

6

Apparatus

7

Test Specimen Configurations, Dimensions and Preparations

8

General Procedures

9

Report (including reporting tables)

11

Precision and Bias

12

Keywords

13

Summary of Changes

Annexes

Test Fixture Geometries

A1

Procedures and Special Requirements for Precracked Beam Method

A2

Procedures and Special Requirements for Surface Crack in Flexure Method

A3

Procedures and Special Requirements for Chevron Notch Flexure Method

A4

Appendices

Precrack Characterization, Surface Crack in Flexure Method

X1

Complications in Interpreting Surface Crack in Flexure Precracks

X2

Alternative Precracking Procedure, Surface Crack in Flexure Method

X3

Chamfer Correction Factors, Surface Crack in Flexure Method Only

X4

Crack Orientation

X5

1.6 Values expressed in these test methods are in accordance with the International System of Units (SI) and Practice E 380.

1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


Note—The figures on the right show the test specimen cross sections and crack types. Four-point loading may be used with all three methods. Three-point may be used with the pb and vb specimens.

FIG. 1 The Three Test Methods

 
2. Referenced Documents

C1161-18(2023)

Standard Test Method for Flexural Strength of Advanced Ceramics at Ambient Temperature

C1322-25

Standard Practice for Fractography and Characterization of Fracture Origins in Advanced Ceramics

E4-24

Standard Practices for Force Calibration and Verification of Testing Machines

E112-25e1

Standard Test Methods for Determining Average Grain Size (Includes all amendments and changes 9/9/2026).

E177-26a

Standard Practice for Use of the Terms Precision and Bias in ASTM Test Methods (Includes all amendments and changes 5/14/2026).

E337-15(2023)

Standard Test Method for Measuring Humidity with a Psychrometer (the Measurement of Wet- and Dry-Bulb Temperatures)

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method

E740-03

Standard Practice for Fracture Testing with Surface-Crack Tension Specimens

E1823-26a

Standard Terminology Relating to Fatigue and Fracture Testing (Includes all amendments and changes 8/27/2026).

IEEE/ASTM SI 10

Standard for Use of the International System of Units (SI) (The Modern Metric System)

NIST SRM 2100

Fracture Toughness of Ceramics Available from National Institute of Standards and Technology (NIST), 100 Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http://www.nist.gov.