ASTM C1488-04 - 1.5.2004
 
Significance and Use

The purpose of this practice is to simulate the aging process of cellulosic loose-fill insulation. By identifying any changes in flame retardant permanency due to the aging process, producers can design loose-fill insulation to meet or exceed material specifications throughout the product life cycle.

 
1. Scope

1.1 This practice covers a procedure to simulate the aging process of cellulosic loose-fill insulation by subjecting it to controlled laboratory conditions of temperature and humidity so that the insulation will be further evaluated, particularly for critical radiant flux characteristics.

1.2 It is not the intent of this practice to establish aging conditions that represent all possible exposures.

1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are provided for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

 
2. Referenced Documents

C687-24

Standard Practice for Determination of Thermal Resistance of Loose-Fill Building Insulation

C739-25

Standard Specification for Cellulosic Fiber Loose-Fill Thermal Insulation

C870-24

Standard Practice for Conditioning of Thermal Insulating Materials

C1485-26

Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using an Electric Radiant Heat Energy Source

E970-25

Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source

C168-25

Standard Terminology Relating to Thermal Insulation