1. Scope

1.1 This test method covers the determination of the Pyrometric Cone Equivalent (PCE) of fire clay, fireclay brick, high alumina brick, and silica fire clay refractory mortar by comparison of test cones with standard pyrometric cones under the conditions prescribed in this test method.

1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are for information only.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

E220-25

Standard Test Method for Calibration of Thermocouples by Comparison Techniques

C71-12(2024)

Standard Terminology Relating to Refractories

E11-24

Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves

E691-23

Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method