ASTM C495-99a - 10.2.1999
 
1. Scope

1.1 This test method covers the preparation of specimens and the determination of the compressive strength of lightweight insulating concrete having an oven-dry weight not exceeding 50 lb/ft (800 kg/m ) as determined by the procedures described herein. This test method covers the preparation and testing of molded 3 by 6-in. (75 by 150-mm) cylinders.

1.2 The values stated in inch-pound units are to be regarded as the standard.

1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

C172-08

Standard Practice for Sampling Freshly Mixed Concrete

C617-10

Standard Practice for Capping Cylindrical Concrete Specimens

C39/C39M-26

Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

C88-13

Standard Test Method for Soundness of Aggregates by Use of Sodium Sulfate or Magnesium Sulfate

C109/C109M-26a

Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 50 mm [2 in.] Cube Specimens) (Includes all amendments and changes 7/30/2026).

C670-24ae1

Standard Practice for Preparing Precision and Bias Statements for Test Methods for Construction Materials (Includes all amendments and changes 2/21/2025).