ASTM C567-05a - 15.12.2005
 
Significance and Use

The measured or calculated equilibrium density of structural lightweight concrete determines whether specified density requirements have been met. Unless otherwise specified, determine equilibrium density by calculation using the procedures in 9.2.

Test Method C 138/C 138M shall be used to determine the density of freshly mixed lightweight concrete for compliance with concrete placement specifications.

Note 1—The fresh density of lightweight aggregate concrete is a function of mixture proportions, air content, water demand, and the specific density and moisture content of the lightweight aggregate. Decrease in density of a specific lightweight concrete is due to moisture loss that, in turn, is a function of aggregate moisture content, ambient conditions, and the ratio of the surface area to the volume of the concrete member. For most structural lightweight concretes, equilibrium density is approached at about 90 days. For most high-strength lightweight concretes, equilibrium density is approached at about 180 days. Extensive tests demonstrate that despite variations in the initial moisture content of lightweight aggregate, the equilibrium density will be approximately 50 kg/m3 (3.0 lb/ft3) greater than the oven-dry density.

 
1. Scope

1.1 This test method provides procedures to determine the oven-dry and equilibrium densities of structural lightweight concrete.

1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.3This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

C88-13

Standard Test Method for Soundness of Aggregates by Use of Sodium Sulfate or Magnesium Sulfate

C125-26

Standard Terminology Relating to Concrete and Concrete Aggregates

C138/C138M-24a

Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete (Includes all amendments and changes 8/6/2024).

C31/C31M-26b

Standard Practice for Making and Curing Concrete Test Specimens in the Field (Includes all amendments and changes 8/27/2026).

C172-08

Standard Practice for Sampling Freshly Mixed Concrete

C470/C470M-23

Standard Specification for Molds for Forming Concrete Test Cylinders Vertically

E104-20a

Standard Practice for Maintaining Constant Relative Humidity by Means of Aqueous Solutions (Includes all amendments and changes 12/21/2020).

C192/C192M-26b

Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory (Includes all amendments and changes 10/13/2026).