ASTM C680-89(1995)e1 - 1.1.1995
 
1. Scope

1.1 The computer programs included in this practice provide a calculational procedure for predicting the heat loss or gain and surface temperatures of insulated pipe or equipment systems. This procedure is based upon an assumption of a uniform insulation system structure, that is, a straight run of pipe or flat wall section insulated with a uniform density insulation. Questions of applicability to real systems should be resolved by qualified personnel familiar with insulation systems design and analysis. In addition to applicability, calculational accuracy is also limited by the range and quality of the physical property data for the insulation materials and systems.

1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

 
2. Referenced Documents

C1055-20

Standard Guide for Heated System Surface Conditions that Produce Contact Burn Injuries

C335-05a

Standard Test Method for Steady-State Heat Transfer Properties of Pipe Insulation

C518-21

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

C585-22

Standard Practice for Inner and Outer Diameters of Thermal Insulation for Nominal Sizes of Pipe and Tubing

NBS Circular 564

Tables of Thermodynamic and Transport Properties of Air, U.S. Dept of Commerce

C168-25

Standard Terminology Relating to Thermal Insulation

C177-19(2026)

Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus

C1057-22

Standard Practice for Determination of Skin Contact Temperature from Heated Surfaces Using a Mathematical Model and Thermesthesiometer