ASTM C688-08 - 1.12.2008
 
1. Scope

1.1 This specification covers methods to investigate the effectiveness of a material to beneficially change the properties of hydraulic cements when the material is incorporated during manufacture of the cement.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 The effect of additions in cement may markedly change properties other than those they are intended to modify. This specification is designed to test for such changes. Table 1 sets forth values for those properties of cement pastes and mortars that would permit a judgment of the changes effected by an addition. Likewise, Table 2 sets forth similar criteria for concrete. Certain additions may be found effective for more than one purpose as indicated in 3.1.4 and 3.1.5.

TABLE 1 Criteria for Evaluating Neat Cement and Mortar Containing Functional Cement Additions

TestsType of Addition
Water Reducing RetardingAcceleratingWater-Reducing
and Retarding
Water-Reducing and
Accelerating
Set-Control

Normal consistency, deviation from control,
percentage pointsA

−1.0 min

+1.0 max

+1.0 max

−1.0 min

−1.0 mm

±1.0 max

Standard consistency (flow) deviation from
control, percentage pointsA

−4.0 min

+2.0 max

+2.0 max

−4.0 min

−4.0 min

±2.0 max

Setting time, (Gillmore) deviation from control,
h:min

Initial

At least

...

1:00 laterB

1:00 laterB

...

Not more than

1:00 earlier

3:30 later

1:30 earlier

3:30 later

1:30 earlier

1:00 earlier

nor

nor

nor

nor

1:30 later

1:30 later

1:30 later

1:30 later

Setting time, Vicat InitialC

At least

...

0:50 laterB

...

...

...

Not more than

0:50 earlier

2:50 later

1:15 earlier

0:50 laterB

1:15 earlier

0:50 earlier

nor

nor

nor

nor

1:15 later

1:15 later

2:50 later

1:15 later

1:15 later

Final

Not more than

1:00 earlier

3:30 later

1:00 earlier

3:30 later

1:00 earlier

1:00 earlier

nor

nor

nor

nor

1:30 later

1:30 later

1:30 later

1:30 later

Compressive strength, min, percent of control:D

1 day in moist air

110

90

125E

90

125

F

1 day in moist air, 2 days in water

110

90

125E

100

125

1 day in moist air, 6 days in water

110

90

100

110

110

1 day in moist air, 27 days in water

110

95

95

110

110

Autoclave Expansion
max increase in % change in length compared to control


0.10


0.10


0.10


0.10


0.10


0.10

Drying Shrinkage of Mortar
max % change in length compared to control


0.020


0.020


0.030


0.020


0.020


0.020

A The minus sign indicates that the percentage of water required shall be less than that of the control cement by at least the indicated percentage points.

B Or 50 % later, whichever is the lesser.

C Either Vicat or the Gillmore time of setting method shall be used at the choice of the manufacturer.

D The compressive strength of mortar containing the test cement shall be not less than 95 % of that attained at any previous test age. The objective of this limit is to require that the strength of mortar containing the addition under test shall not decrease with age.

E In cases where the accelerated set time only is required, the strength can be reduced to 100 % of the control.

F The grand average of the 1, 3, 7, and 28-day strengths shall be not less than 95 % of the grand average for the corresponding control cement.

TABLE 2 Criteria for Evaluating Concrete Containing Functional Cement AdditionsA

TestsType of Addition
Water Reducing RetardingAcceleratingWater-Reducing
and Retarding
Water-Reducing
and Accelerating

Water content, max, percent of control

95

...

...

95

95

Time of setting, (penetration) deviation from
control, h:min:

Initial

At least

...

1:00 laterB

1:00 laterB

Not more than

1:00 earlier

3:30 later

3:30 earlier

3:30 later

3:30 earlier

nor

Final

1:00 later

Not more than

1:00 earlier

3:30 later

...

3:30 later

...

nor

1:30 later

Compressive strength, min, percent of
control:C

1 dayD

110

85

125E

100

125

3 days

110

85

125E

100

125

7 days

110

90

100

110

110

28 days

110

90

95

110

110

3 months

100

90

95

100

100

1 year

100

90

95

100

100

Flexural strength, min, percent of
control:C

1 dayD

100

85

110

90

110

3 days

100

85

110

100

110

7 days

100

90

100

100

100

28 days

100

90

90

100

100

3 months

100

90

90

100

100

1 year

100

90

90

100

100

Bond strength, percent of control:

28 days

100

90

100

100

100

Volume change, expressed as change in
length, max, increase over control,
percentage points:

28 days

0.010

0.010

0.030

0.010

0.010

3 months

0.010

0.010

0.030

0.010

0.010

1 year

0.010

0.010

0.030

0.010

0.010

Durability factor, min, percent of controlF

80

80

80

80

80

A The values in the table are intended to allow for normal variation in test results. For example, the object of the 90 % compressive strength requirement for a retarding addition is to require a level of performance comparable to that of the reference concrete.

B Or 50 % later, whichever is the lesser.

C The compressive and flexural strength of the concrete containing the addition under test at any test age shall be not less than 90 % of that attained at any previous test age. The objective of this limit is to require that the compressive or flexural strength of the concrete containing the addition under test shall not decrease with age.

D One-day strengths applicable only to Type III cement. One-year strength tests shall be made; however, the addition may be approved after completion of the 3-month strength results, at the discretion of the purchaser.

E In cases where the accelerated set time only is required, the strength can be reduced to 100 % of the control.

F This requirement is applicable only when the addition is to be used in air-entrained concrete.

 
2. Referenced Documents

C232-07

Standard Test Methods for Bleeding of Concrete

C234-91a

Standard Test Method for Comparing Concretes on the Basis of the Bond Developed with Reinforcing Steel (Withdrawn 2000)

C266-21

Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles

C403/C403M-23

Standard Test Method for Time of Setting of Concrete Mixtures by Penetration Resistance

C451-21

Standard Test Method for Early Stiffening of Hydraulic Cement (Paste Method)

C465-25

Standard Specification for Processing Additions for Use in the Manufacture of Hydraulic Cements

C595-08

Standard Specification for Blended Hydraulic Cements

C596-23

Standard Test Method for Drying Shrinkage of Mortar Containing Hydraulic Cement

C666/C666M-26

Standard Test Method for Resistance of Concrete to Rapid Freezing and Thawing

C845-04

Standard Specification for Expansive Hydraulic Cement

C10/C10M-24a

Standard Specification for Natural Cement (Includes all amendments and changes 12/25/2024).

C39/C39M-26

Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens

C78-09

Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading)

C109/C109M-26a

Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 50 mm [2 in.] Cube Specimens) (Includes all amendments and changes 7/30/2026).

C143/C143M-26b

Standard Test Method for Slump of Concrete (Includes all amendments and changes 8/6/2026).

C150-07

Standard Specification for Portland Cement

C151-05

Standard Test Method for Autoclave Expansion of Hydraulic Cement

C157/C157M-24e1

Standard Test Method for Length Change of Hardened Hydraulic-Cement Mortar and Concrete (Includes all amendments and changes 10/14/2024).

C1157-08

Standard Performance Specification for Hydraulic Cement

C187-25

Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste

C219-25

Standard Terminology Relating to Hydraulic and Other Inorganic Cements

C226-22

Standard Specification for Air-Entraining Additions for Use in the Manufacture of Air-Entraining Hydraulic Cement