ASTM C697-04 - 1.1.2004
 
Significance and Use

Plutonium dioxide is used in mixtures with uranium dioxide as a nuclear-reactor fuel. In order to be suitable for this purpose, the material must meet certain criteria for plutonium content, isotopic composition, and impurity content. These test methods are designed to show whether or not a given material meets the specifications for these items as described in Specification C 757.

3.1.1 An assay is performed to determine whether the material has the minimum plutonium content specified on a dry weight basis.

3.1.2 Determination of the isotopic content of the plutonium in the plutonium dioxide powder is made to establish whether the effective fissile content is in compliance with the purchaser’specifications.

3.1.3 Impurity content is determined to ensure that the maximum concentration limit of certain impurity elements is not exceeded. Determination of impurities is also required for calculation of the equivalent boron content (EBC).

 
1. Scope

1.1 These test methods cover procedures for the chemical, mass spectrometric, and spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets to determine compliance with specifications.

1.2 The analytical procedures appear in the following order:

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Sections 6, 15, 24, 111, and 52.9 and 101.5.1.

 
2. Referenced Documents

E115-97

Standard Practice for Photographic Processing in Optical Emission Spectrographic Analysis (Withdrawn 2002)

E60-11(2022)e1

Standard Practice for Analysis of Metals, Ores, and Related Materials by Spectrophotometry (Includes all amendments and changes 6/29/2022).

D4327-17(2025)

Standard Test Method for Anions in Water by Suppressed Ion Chromatography

E130-08

Standard Practice for Designation of Shapes and Sizes of Graphite Electrodes (Withdrawn 2013)

C1415-24

Standard Test Method for 238Pu Isotopic Abundance by Alpha Spectrometry

D1193-24

Standard Specification for Reagent Water

C1672-23

Standard Test Method for Determination of the Uranium, Plutonium or Americium Isotopic Composition or Concentration by the Total Evaporation Method Using a Thermal Ionization Mass Spectrometer

C1637-21

Standard Test Method for Determination of Impurities in Plutonium Materials—Acid Digestion and Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) Analysis

C1625-24

Standard Test Method for Uranium and Plutonium Concentrations and Isotopic Abundances by Thermal Ionization Mass Spectrometry

C1432-23

Standard Test Method for Determination of Impurities in Plutonium: Acid Dissolution, Ion Exchange Matrix Separation, and Inductively Coupled Plasma-Atomic Emission Spectroscopic (ICP/AES) Analysis

C1068-21

Standard Guide for Qualification of Measurement Methods by a Laboratory Within the Nuclear Industry

C859-26

Standard Terminology Relating to Nuclear Materials

C852-09

Standard Guide for Design Criteria for Plutonium Gloveboxes

C757-16(2021)

Standard Specification for Nuclear-Grade Plutonium Dioxide Powder for Light Water Reactors

C1307-21

Standard Test Method for Plutonium Assay by Plutonium (III) Diode Array Spectrophotometry

E116-97

Standard Practice for Photographic Photometry in Spectrochemical Analysis (Withdrawn 2002)

C1235-99

Standard Test Method for Plutonium by Titanium(III)/Cerium(IV) Titration (Withdrawn 2005)

C1233-15(2021)

Standard Practice for Determining Equivalent Boron Contents of Nuclear Materials

C1206-02

Standard Test Method for Plutonium by Iron (II)/Chromium (VI) Amperometric Titration

C1168-23

Standard Practice for Preparation and Dissolution of Plutonium Materials for Analysis

C1165-23

Standard Test Method for Determining Plutonium by Controlled-Potential Coulometry in H2SO4 at a Platinum Working Electrode

C1108-23

Standard Test Method for Plutonium by Controlled-Potential Coulometry

C1268-23

Standard Test Method for Quantitative Determination of 241Am in Plutonium by Gamma-Ray Spectrometry