Significance and Use

4.1?Simple and complex fluoride ions are found in natural waters. Fluoride forms complexing ions with silicon, aluminum, and boron. These complexes may originate from the use of fluorine compounds by industry.

4.2?Fluoridation of drinking water to prevent dental caries is practiced by a large number of communities in this country. Fluoride is monitored to assure that an optimum treatment level, usually near 1 mg/L, is maintained.

 
1. Scope

1.1?These test methods2 cover the determination of fluoride ion in water. The following two test methods are given:

?

Sections

Test Method ADistillation

7 to 13

Test Method BIon Selective Electrode

14 to 21

1.2?Test Method A covers the accurate measurement of total fluoride in water through isolation of the fluoride by distillation and subsequent measurement in the distillate by use of the ion selective electrode (ISE) method. The procedure covers the range from 0.1 to 2.6 mg/L of fluoride.

1.3?Test Method B covers the accurate measurement of simple fluoride ion in water by means of an ion selective electrode. With this test method, distillation is eliminated because the electrode is not affected by the interferences common to colorimetric procedures. Concentrations of fluoride from 0.1 to 1000 mg/L may be measured.

1.4?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For a specific precautionary statement, see 12.1.2.

1.6?Former Test Method A, SPADNS Photometric Procedure, was discontinued. Refer to Appendix X1 for historical information.

1.7?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

D2777-21

Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water

D5810-96(2021)

Standard Guide for Spiking into Aqueous Samples

D1193-06(2018)

Standard Specification for Reagent Water

D1129-13(2020)e2

Standard Terminology Relating to Water (Includes all amendments and changes 2/14/2024).

D1066-18e1

Standard Practice for Sampling Steam (Includes all amendments and changes 12/31/2018).

D5847-22

Standard Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis

D4127-18a

Standard Terminology Used with Ion-Selective Electrodes (Includes all amendments and changes 6/29/2018).

D3370-18

Standard Practices for Sampling Water from Flowing Process Streams