ASTM D4597-10(2021) - 1.3.2021
 
Significance and Use

5.1?Regulations such as those promulgated by the U.S. Occupational Safety and Health Administration in Title 29CFR 1910.1000 designate that certain hazardous gases and vapors must not be present in the workplace air at concentrations above specific values.

5.2?This practice, when used in conjunction with an analytical technique, such as that given for organic compounds in Test Method D3687, may provide a means for the determination of time-weighted airborne concentrations of many of the hazardous gases and vapors in applicable regulations (for example, Title 29CFR 1910.1000), as well as others.

5.3?The manufacturers literature should be consulted for the appropriate list of chemicals which may be sampled by a particular device.

 
1. Scope

1.1?This practice covers the sampling of workplace atmospheres for the presence of certain gases or vapors by means of diffusion across a specified quiescent region and subsequent sorption on a solid sorbent (1).2

1.2?A list of organic compounds which are applicable to solid sorbent sampling where the sorbent is contained in a bed through which air is passed is given in Annex A1 of Practice D3686. Diffusive samplers may be applicable to a similar range of compounds but this must be confirmed by reference to the individual sampler manufacturers literature.

1.3?The valid use of diffusive samplers depends on the existence of actual laboratory or field validation, or both. Guidance on validation can be obtained from published protocols (2-6). This practice is not designed to cover the verification, validation, or specific test procedures used to assess the accuracy or precision of diffusive samplers.

1.4?The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

 
2. Referenced Documents

D3687-19

Standard Test Method for Analysis of Organic Compound Vapors Collected by the Activated Charcoal Tube Adsorption Method

D1356-20a

Standard Terminology Relating to Sampling and Analysis of Atmospheres (Includes all amendments and changes 9/7/2020).

D3686-20

Standard Practice for Sampling Atmospheres to Collect Organic Compound Vapors (Activated Charcoal Tube Adsorption Method)

D6306-17

Standard Guide for Placement and Use of Diffusive Samplers for Gaseous Pollutants in Indoor Air